KH1508Ai / KH1516Ai User Manual
114
IP Installer
The IP Installer is an external Windows-based utility for assigning IP addresses
to the KH1508
Ai / KH1516Ai.
Click one of the radio buttons to select Enable, View Only, or Disable for the
IP Installer utility. See IP Installer, page 173, for IP Installer details.
Note: 1. If you select View Only, you will be able to see the KH1508Ai /
KH1516
Ai in the IP Installer’s Device List, but you will not be able
to change the IP address.
2. For security, we strongly recommend that you set this to View Only
or Disable after each use.
Service Ports
As a security measure, if a firewall is being used, the Administrator can specify
the port numbers that the firewall will allow. If a port other than the default is
used, users must specify the port number as part of the IP address when they
log in. If an invalid port number (or no port number) is specified, the
KH1508
Ai / KH1516Ai will not be found. An explanation of the fields is given
in the table below:
Note: 1. Valid entries for all of the Service Ports are from 1–65535.
2. Service ports cannot have the same value. You must set a different
value for each one.
3. If there is no firewall (on an Intranet, for example), it doesn’t matter
what these numbers are set to, since they have no effect.
Field Explanation
Program This is the port number for connecting with the WinClient
ActiveX Viewer, WinClient AP, Java Applet Viewer, Java Client
AP, or via Virtual Media. The default is 9000.
HTTP The port number for a browser login. The default is 80.
HTTPS The port number for a secure browser login. The default is 443.